News & FAQ

ALL

Home > News & FAQ > ALL

IEC 60598-1:2024, Edition 10.0 List Apparatus

Add time:2025-07-03   Clicks:28   [Return]

TESTING AND MEASURINGEQUIPMENT/ALLOWED SUBCONTRACTING

IEC 60598-1:2024, Edition 10.0

Luminaires - Part 1: General requirements and tests

Abbreviations tobe used at the column “Equipment Classification”:

“R”            Required

“S”            Maybe subcontracted, see OD 2012

“SP”          SpecializedFacility, see IECEE 02-2

“W”           Witnesstesting in the categories “MED” and “MEAS”

“3PPS”       Three Phase Power Supply required

Clause

Measurement/testing

Testing   / measuring equipment / material needed

Equipment   Classification

6.5

Test of  marking

Piece  of cloth / Water / Petroleum spirit

R

7.4.4

Lampholder  pressure test

Test  caps / Pressure device / Torque driver

R

7.4.5

Voltage  across lampholders

High  voltage probe / Oscilloscope

R

7.7.7

Multi-pole  plug and socket

Force  meter (30 N) / Timer

R

7.9.2

Insulating  linings and sleeves tests

Heating  cabinet

R

7.10.2

Openings  in double or reinforced insulation

Test  probe 13 of IEC 61032:1997, Figure 9

R

7.11.6

Electro-mechanical  contact system

Low  voltage variable current power supply / Voltmeter / High voltage source

R

7.12.1
 7.12.3
 7.12.4

Screws  and connections (mechanical) and glands testing

Test  screwdriver or spanner / Test rods

R

7.13.1
 7.21.4

Mechanical  strength tests

Spring-operated  impact test apparatus according to IEC 60068-2-75 (other suitable means  giving equivalent results)/ Test screwdriver or spanner

R

7.13.3

Mechanical  strength tests

Test  probe 11 of IEC 61032:1997, Figure 7 / Force meter (30 N)

R

7.13.4  

Mechanical  strength tests

Tumbling  barrel test equipment of IEC 60068-2-31:2008, 5.3

R

7.14.1
 7.14.2
 7.14.3

Adjusting  devices testing

Glass  test shelves / Weighting device / Test apparatus for adjustable devices / Torque  measuring equipment / Timer

R

7.18.1

Resistance  to corrosion

Test solution  / Heating cabinet / Humidity cabinet

R

7.18.2
 Annex F

Stress  corrosion

Closeable  glass vessel / Test solution / Heating cabinet / Facilities to wash samples  after test

R

7.20.1

Resistance  to vibrations for rough service luminaires

Vibration  test equipment

S

7.20.2

Rough  service luminaires

Steel  sphere / Conditioning cabinet (e.g. freezer) / Inclined plane (6°and 15°) or angle  measuring device

R

7.22

Attachment  to lamps

Weighing  device

R

7.24
 Annex M

Photobiological  hazards

Equipment  list of IEC 62471-7:2023

S

Alternative,  for retinal blue light hazard only, the equipment list of IEC/TR 62778

S

7.26

Short  circuit protection test

Test  chain / Weighting device

R

7.27
 Annex R

Terminal  blocks with integrated screwless protective earthing contact

Force  meter (20 N / 50 N) / Timer / Earthing test equipment (9.2.3)

R

7.28

Fixing  of thermal sensing controls

Temperature  change test instruments of
 IEC 60068-2-14:2023(test Na)

S

7.32.3.6

SPC  overload test

AC  power supply source / Variable loads / High-frequency spark generator

R

7.34

Electromagnetic  fields

Equipment  list of IEC 62493:2015 + AMD1:2022

S

7.35

Protection  against moving fan blades

Test  probe B of IEC 61032:1997, Figure 2 / Test probe 19 of IEC 61032:1997, Figure  13

R

Hardness  test equipment acc. to ISO 48-4:2018 / Equipment to measure peripheral speed

S

8.2.10.3

Pull  and torque tests on cord anchorage

Cord  anchorage tests apparatus (pull and torque)

R

8.2.14

Plug  test

Continuity  tester (Figure 34)

R

8.3

Internal  wiring dimensions

Micrometer /  Equipment for insulation thickness

R

8.4

Test of  conductors having a reduced cross-sectional area

Thermometer  / Thermocouples / Ammeter / Adjustable resistive load

R

9.2.3

Earth  continuity test

Earthing  test equipment

R

10.2.5

Protection  against electric shock tests

Test  probe B of IEC 61032:1997, Figure 2 / Test probe A of IEC 61032:1997, Figure  1 / Test circuit for safety during insertion (Figure 19)

R

10.2.6

Covers

Force  meter (20 N / 80 N)

R

10.2.7

Capacitor  discharge

Oscilloscope  / Test probe B of IEC 61032:1997, Figure 2

R

11.2.2

Tests  for first characteristics IP numerals 2, 3 and 4

Test  probe B of IEC 61032:1997, Figure 2 /
 Test probe C of IEC 61032:1997, Figure 3 /
 Test probe D of IEC 61032:1997, Figure 4

R

11.2.3

Tests for  first characteristic IP numeral 5 and 6

Apparatus  for proving protection against dust

R

11.2.4
 11.2.5

Drip-proof  luminaires testing

Apparatus  for protection against water IPX1 and   IPX2

R

11.2.6
 11.2.7

Rain-proof  and splash-proof luminaires testing

Apparatus  for protection against water IPX3 and IPX4

R

11.2.8
 11.2.9

Jet-proof  and powerful jet-proof luminaires

Apparatus  for protection against water IPX5 and IPX6

R

11.2.10

Watertight  luminaires

Apparatus  for protection against water IPX7

R

11.2.11

Pressure  watertight luminaires

Apparatus  for protection against water IPX8

S

11.2.8
 11.2.9

High  pressure water jet-proof luminaires

Apparatus  for protection against water IPX9 (15 °C / 80 °C)

S

11.3.1

Humidity  tests

Humidity  cabinet / Timer

R

12.2.2

Insulation  resistance tests

Insulation  resistance meter

R

10.2.3

Electric  strength tests

High  voltage test equipment

R

12.3
 Annex G

Touch  current and protective conductor current test

Test setup (Figure G.1) / Measuring networks  (Figures G.2, G.3 and G.4) / Test probe B of IEC 61032:1997, Figure 2 /  Oscilloscope

R

13.2.1

Creepage  distances and clearances measurements

Digital  calliper (or equivalent) / Oscilloscope / Test probe B of IEC 61032:1997,  Figure 2

R

13.2.1

Reductions  for creepage distances and clearances by the use of coating or potting

Equipment  list of IEC 61347-1:2015, Annex P

S

14.3.2
 W.6.1

Endurance  tests

Thermal  cabinet / Endurance test equipment / Multimeter /  Wattmeter / Timer

R

14.4.2
 Annex D
 Annex E
 W.6.2

Thermal  tests

Draught-proof  enclosure or alternative chamber/room / Thermometer / Thermocouples / Voltage  stabilizer / Multimeter / Wattmeter / Wheatston bridge or suitable measuring instrument /  Timer

R

14.5.2
 Annex C

Abnormal  operation testing

Force  meter (30 N) / Test circuit of Figure C.3

R

14.7.3

Test  for luminaires with temperature sensing controls internal/external to the  ballast or transformer

Equipment  List of IEC 61558-1:2017, 15.3, 20.8, 20.9

R

15.2.2

Resistance  to heat test

Heating  cabinet / Ball pressure test apparatus
 (see also CTL DSH 391 D)

R

15.3.2

Resistance  to flame test

Needle  flame test apparatus

R

15.3.3

Resistance  to ignition testing

Glow-wire  test apparatus

R

15.4.2

Resistance  to tracking test

Proof  tracking test device

R

16

Screw  terminals

Torque  drivers / Test cables / Pull device / Micrometer / Timer

R

17

Screwless  terminals

Pull  device / Variable current source / Voltmeter / Heating cabinet / Timer / Test  cables

R

A.2

Touch voltage  measurement

Non-inductive  resistance of 50 kΩ / Voltmeter

R

W.2

General  test

Artificial source (Table W.1)  – if used

S

W.4.2

Smal  Batteries

Cylinder  of ISO 8124-1:2022, 5.2 / Timer / Force meter (10 N /30 N / 50 N) / Test  probe 11 of IEC 61032:1997, Figure 7 / Test fingernail of IEC 60335-1:2020,  Figure 7 / Torque meter (2 Nm / 4 Nm) / Cylindrical metallic mass (1 kg / 80  mm)

R

W.4.3

Battery  compartment fasteners

Force  meter (20 N) / Timer

R

W.4.5

Short-circuit  protection

Test  probe 13 of IEC 61032:1997, Figure 9 / Resistance meter / Timer / Temperature  measurement

S

W.4.6.1

General  conditions for testing lithium-ion battery charging

Single  pole resistive-capacitive low pass filter (cut-off frequency of 5 kHz ± 500  Hz) / Thermocouples / Voltmeter / Ammeter / Timer

S

W.4.7

Protection  against overpressure for Li-ion batteries

Apparatus designed to deliver 20; 30; 50; 100  ml ± 10 % of air at an initial pressure of 2 070 kPa ± 10 % through a (2,85 ±  0,05) mm diameter orifice / Pressure gauge / Timer

S

W.6.3

Thermal  test (abnormal operation)

Equipment as required in 14.5.2

S

W.6.4

Lithium-ion charging systems – Fault  conditions

Equipment list of IEC 61347-1:2015 and
 IEC 61347-1:2015/AMD1:2017, Clause 14

S